Skip to content
Milan · Como · Since 2010SIM + SMPP / HTTP
FoxBox
Menu

CLUSTER & REDUNDANCY

Build continuity into
your FoxBox deployment.

Two Single units or one Redundant configuration. Plan a two-node architecture with a virtual IP, a dedicated heartbeat and automatic failover of the access point.

Topology confirmed by FoxBox · cluster mechanism reviewed in source · hardware failover test still required

YOUR APPLICATIONSOne virtual IP address

The active node owns the shared access point.

MASTER / ACTIVE

Node A

Serves the virtual IP while healthy

↔Dedicated heartbeat
Keepalived / VRRP
BACKUP / STANDBY

Node B

Can take over the virtual IP

Access failover is one part of the design.State, queues, modem routes and delivery need their own validation.

TWO WAYS TO PLAN THE CLUSTER

Choose the topology.
Then confirm the hardware.

“Single” and “Redundant” identify deployment options here. They do not mean every S1, S2 or SR configuration has the same cluster capability.

01 / TWO SINGLE UNITS

Two appliances.
A coordinated pair.

Scope two FoxBox Single units as the cluster nodes. Review placement, power, network links and modem/SIM allocation for each appliance. Separate units let you plan separate failure boundaries; the actual independence must be checked in the installation.

Discuss two Single units ↗
02 / REDUNDANT CONFIGURATION

One Redundant system.
A defined node design.

Scope a FoxBox Redundant configuration with the required node roles. Confirm the exact hardware layout and which components, power sources and network paths are shared. Redundant hardware still needs an explicit failure and recovery plan.

Discuss a Redundant system ↗

THE IMPLEMENTED MECHANISM

A shared address.
Two explicit roles.

The reviewed cluster setup defines a preferred MASTER and a BACKUP using Keepalived with unicast VRRP. A dedicated heartbeat interface carries the node relationship; the virtual IP sits on the client LAN. Priority and health tracking determine which node owns that address.

The health check in the reviewed setup checks the local web proxy container and an HTTP response. It does not establish modem availability, database health, message-queue progress or final SMS delivery. The project must decide whether additional health criteria are needed for its operating requirements.

Applications target the agreed virtual endpoint. A node transition can interrupt a request already in flight. An ambiguous submission must be reconciled before a retry, because sending the same SMS again can create a duplicate.

DESIGN THE COMPLETE SERVICE

Access, data and delivery
are separate responsibilities.

01

State and queues

Identify where users, configuration, message queues and delivery records live, and how they are synchronized or recovered. The reviewed access-failover scripts do not by themselves prove database replication or exactly-once processing.

02

Network partitions

Test what happens if the heartbeat link fails while both nodes can still reach the client LAN. Confirm the installation’s split-brain protection, fencing or equivalent operational controls before relying on automatic takeover.

03

Recovery and ownership

Define whether the preferred node takes the virtual IP back automatically, how interrupted work is reconciled, and who approves a return to normal operation. Node recovery and service recovery are not necessarily the same moment.

ACCEPTANCE TESTS

Prove the failure modes
that matter to your site.

  1. Record exact models, node software, firmware, interfaces, virtual endpoint and routing configuration. Validate with synthetic transports first.
  2. Test active-node shutdown, proxy failure, client-LAN failure and heartbeat isolation separately. Record virtual-IP ownership on both nodes throughout each event.
  3. Submit synthetic requests before, during and after transition. Trace accepted, rejected, ambiguous and duplicate requests, then inspect queue and state recovery.
  4. Restore the original node and verify the chosen failback policy. Confirm the monitoring signals and the operator recovery procedure.
  5. For an explicitly approved later hardware test, observe each intended SMS route and delivery state. Measure interruption under that test configuration; do not turn it into a universal uptime promise.

SIZE THE PROJECT SEPARATELY

Modem capacity.
Cluster behavior.
Hybrid routes.

These are three project decisions. The standard catalog covers S1, S2 and SR configurations; modem-pool projects can be scoped at 8, 16 or 32 modems, with a maximum arrangement of two 32-modem units. Two modem pools do not automatically constitute a failover cluster.

Local SIM routes and external SMPP/HTTP services through Kannel can be considered in the architecture. The cluster design must explicitly account for how each route behaves when the active node changes.

COMMON QUESTIONS

Be precise about continuity.

Does a virtual IP guarantee uninterrupted SMS delivery?

No. The virtual IP addresses access continuity. Database state, queues, in-flight requests, modem/provider routes and delivery must be tested separately for the chosen deployment.

Can I use any two FoxBox models?

The proposed options are two Single units or a Redundant configuration, as confirmed by FoxBox. Exact model pairing, hardware layout and software compatibility must be specified in the project.

Is 2 × 32 a single 64-modem product?

No. The maximum arrangement discussed here uses two distinct 32-modem units. It is a quotation-based project configuration, and modem count alone does not establish redundancy.

MAKE CONTINUITY A PROJECT REQUIREMENT

Bring your failure scenario.
Build a reviewable plan.

↑

Contact US